Choose a site to explore
Start with a drawing, then turn the model and walk through its parts, power and cooling. These are illustrations of types, not plans of particular facilities. Layouts vary; the drawings are not to scale.
The pictures illustrate parts, not relative size, capacity or efficiency. These categories can overlap. Follow power or cooling to read the steps, then open a step in 3D.
Hyperscale data centers are large-scale facilities built and run by major technology companies that deploy internet services and platforms at massive scale. This page calls a site with several of these buildings a campus.[1]
Questions to ask about this type
- Which company will use this campus, and does a public filing name it or only a project company?
- How many buildings are planned, in what phases, and which phases are approved, under construction or operating?
- Where will the electricity come from: new plants on the utility’s system, a special contract, or generation on the site?
- Is any figure a request, a contract, a design or a measurement, and what does it cover?
- How does the design release heat in the hottest weather, and how much water does that use?
- If there is generation on the site, can the campus also draw from the grid or send power back?
A colocation data center, also called multitenant, rents space to companies that host their own hardware there, with power, cooling, security and networking provided.[1]
Questions to ask about this type
- Who builds and runs the site, and who are the tenants, if any are named?
- Is capacity leased whole to one tenant or divided among several?
- Is the megawatt figure critical IT load under a lease, a utility request or a generator rating?
- Which phases are leased, which are built and which are operating?
- Who is responsible for cooling and for reporting its water use, the landlord or the tenant?
A carrier hotel, or telecom hotel, is a building where a commercial landlord rents floor space to many network companies, as a 2003 federal report defined it.[2]
Questions to ask about this type
- Who owns the building, and who are the tenants on record?
- Where do networks physically meet in the building, and who controls that room?
- How many ways can fiber enter the building, and do carriers share them?
- Does a floor-area figure cover the whole building or only data-center space?
- Does any electricity figure cover one tenant or the whole building?
An enterprise data center is run by an organization, internally, for its own use.[1]
Questions to ask about this type
- Which organization runs it, and does it serve only that organization?
- Is it a separate building or a room inside a larger one?
- Is it the main site or a backup, and where is the other site?
- What keeps it running in a power loss: how many feeds, batteries and generators?
- For a public agency, is the space owned or leased, and what does the agency report about it?
An edge site is a small place to run computing out across a network: a closet, a small room or a very small data center.[1]
Questions to ask about this type
- How big is it in fact, and is “edge” a description of its use or a sales word?
- Whose network or service does it support?
- Where does the building or container sit, and what else shares the site?
- Does it have its own backup, or does it rely on the host site?
- How does it reject heat, and is any of that heat reused?
What the sources say differs
Hyperscale campus and Colocation and leased campuses
- Colocation is built to lease to others. A hyperscale site is built by the company that runs the services on it.[1] Read in the Hyperscale campus guide
- A hyperscale builder runs its own services on the site. A colocation builder leases to others.[1] Read in the Colocation and leased campuses guide
- Assumption in Lawrence Berkeley National Laboratory’s 2024 model: AI is not only hyperscale: the same model puts half of accelerated AI server load in large-scale colocation.[1] Read in the Colocation and leased campuses guide
Hyperscale campus and Carrier hotel (telecom hotel)
These guides do not make a direct comparison of this pair. Use the individual definitions and questions above; no additional difference is inferred here.
Hyperscale campus and Enterprise and government
- An enterprise data center serves one organization’s own internal use. A hyperscale site runs services at massive scale.[1] Read in the Hyperscale campus guide
- Internal sites are midsize on average, about 2,700 square feet.[1] That is an average for the category, not any one site. Read in the Enterprise and government guide
- Internal sites dominated the industry in the early 2010s, and estimates since then show a shift toward hyperscale and colocation.[1] Read in the Enterprise and government guide
Hyperscale campus and Edge sites
- Assumption in Lawrence Berkeley National Laboratory’s 2024 model: A national lab’s model treats edge sites as small, with lower power-supply efficiency and narrower temperature ranges.[1] That is an assumption about categories, not a ranking. Read in the Hyperscale campus guide
- A hyperscale site is built at massive scale. Edge sites are small and placed out across a network.[1] Read in the Edge sites guide
Colocation and leased campuses and Carrier hotel (telecom hotel)
- A carrier hotel is defined by carriers interconnecting, and colocation by leasing space and services. The two can overlap.[2] Read in the Colocation and leased campuses guide
- It overlaps with colocation: colocation is defined by leasing space, a carrier hotel by providers interconnecting.[1] Read in the Carrier hotel (telecom hotel) guide
Colocation and leased campuses and Enterprise and government
- Assumption in Lawrence Berkeley National Laboratory’s 2024 model: A national lab’s model places colocation between small sites and hyperscale for power-supply and airflow efficiency.[1] That is an assumption it shares with internal and communications data centers, and it is not a ranking. Read in the Colocation and leased campuses guide
- A colocation operator leases space to others. Here the operator runs the space for itself.[1] Read in the Enterprise and government guide
Colocation and leased campuses and Edge sites
These guides do not make a direct comparison of this pair. Use the individual definitions and questions above; no additional difference is inferred here.
Carrier hotel (telecom hotel) and Enterprise and government
These guides do not make a direct comparison of this pair. Use the individual definitions and questions above; no additional difference is inferred here.
Carrier hotel (telecom hotel) and Edge sites
- A carrier hotel is a landlord’s building with many tenants. A telecom edge site is the communications company’s own equipment.[1] Read in the Edge sites guide
Enterprise and government and Edge sites
- Branch-office closets and server rooms are smaller still, and are counted separately.[1] Read in the Enterprise and government guide
- Federal reporting draws a line here: the budget office treats small server closets and telecom closets as spaces not designed to be data centers.[3] That is federal reporting only, and it does not decide what counts as an edge site elsewhere. Read in the Edge sites guide
The five types on these pages
| Type | What it is | One example |
|---|---|---|
| Hyperscale campus | Hyperscale data centers are large-scale facilities built and run by major technology companies that deploy internet services and platforms at massive scale. This page calls a site with several of these buildings a campus.[1] | Meta Richland Parish Data Center |
| Colocation and leased campuses | A colocation data center, also called multitenant, rents space to companies that host their own hardware there, with power, cooling, security and networking provided.[1] | Polaris Forge 1 |
| Carrier hotel (telecom hotel) | A carrier hotel, or telecom hotel, is a building where a commercial landlord rents floor space to many network companies, as a 2003 federal report defined it.[2] | 60 Hudson Street |
| Enterprise and government | An enterprise data center is run by an organization, internally, for its own use.[1] | VELCO New Haven Operations Facility |
| Edge sites | An edge site is a small place to run computing out across a network: a closet, a small room or a very small data center.[1] | Greensparc Cordova Data Center (Humpback Creek Hydro) |
These pages use 5 examples chosen by hand. Most records on this site are not typed. 3,110 of the 3,115 source listings on the opening map have no type assigned here. Listings can overlap, so neither number counts distinct data centers.
AI workloads and on-site power do not have pages of their own. Both are covered inside the hyperscale page: AI workloads and on-site power.
Closer looks at parts of a site
- A megawatt of what? Real figures placed on the part of a site each one describes.
- Closed loop, decoded What the phrase establishes about cooling, and what it leaves open.
- Inside one row of servers Where the air goes, in a labeled cutaway of a rack.
Go further on this site
How data centers work · The 3D map · The full map
Sources
- 2024 United States Data Center Energy Usage Report (LBNL-2001637). Lawrence Berkeley National Laboratory. National laboratory. Cited at Table 4.1, p. 36; p. 36; p. 42; pp. 42-43; p. 38; p. 35; p. 37. Captured 3 November 2026.
- Vulnerabilities Task Force Report, Concentration of Assets: Telecom Hotels. President's National Security Telecommunications Advisory Committee, hosted by CISA. Government. Cited at section 3.0, pp. 1-2; section 3.0. Captured 3 November 2026.
- M-19-19, Update to Data Center Optimization Initiative. Executive Office of the President, Office of Management and Budget. Government. Cited at p. 4. Captured 3 November 2026.
Each type’s page lists all of its own sources.